CMC Upgrade Kernel Test Template

Purpose

Validate CMC behavior across staged kernel upgrades on a cloned VM, including reinstall, migration health, service health, and cleanup.

Scope

  • Run per source host provided by operator.
  • Work only on the cloned VM created for this test.
  • If the operator asks to run tests/cmc-upgrade-kernel-test.md or any variation of the "cmc upgrade kernel test" for an ATVM host, treat that request as referring to this file and this workflow only.
  • Treat this file as the source of truth for this test and ignore unrelated workflow references unless the operator explicitly asks to incorporate them for the current request.

Inputs

  • Source VM hostname: <atvmxxx-...>
  • vCenter target/source location: <cluster/datastore/folder>
  • Required clone datastore: AutomatedTest-UnitTesting
  • Default clone ESXi host: CDS1-ESX165 / 192.168.1.165 unless the operator explicitly specifies otherwise
  • Initial clone access host/IP: <INITIAL_CLONE_HOST_OR_IP>
  • SSH username variable: <SSH_USER_VAR>
  • SSH password variable: <SSH_PASSWORD_VAR>
  • Cirrus profile/project: gcstage / skidamarink

Credential Source

  • Use credentials from: /home/cirrus/cds/.env.credentials.local
  • Do not hardcode usernames/passwords in test records or commands.
  • Before any vCenter, SSH, Red Hat subscription, or CMC action, load credentials with set -a; source /home/cirrus/cds/.env.credentials.local; set +a.
  • Verify required credential variable names are present without printing secret values.
  • Do not parse the credential file with grep/awk as the authority; source it and inspect the environment because entries may use export KEY=....

CMC Tooling Rule (Global)

  • For all CMC-related actions in this test, use the cirrusdata skill/CLI path.
  • Exception: offline-host cleanup is not handled by that skill yet; use the MCP connection for offline-host removal.
  • Apply this rule to every relevant step in this procedure.
  • For every CMC install/reinstall command in this test, always include installer option: -no-prebuilt-mtdi-nexus.

Kernel Package Matching Rule (Global)

  • For every planned kernel upgrade, verify matching development/header packages are available for the exact target kernel version before installing that kernel.
  • On Red Hat-family systems, verify kernel-devel-<target> and kernel-headers-<target> availability (or documented distro-equivalent package names where applicable).
  • The first kernel upgrade attempt must not use the latest kernel in the filtered candidate list; reserve the latest kernel for the final kernel-upgrade stage.
  • When upgrading kernel versions, also upgrade/install the matching development/header packages for that same version.
  • After each kernel upgrade and reboot, verify running kernel version and installed dev/header package versions all match.
  • If kernel and dev/header package versions are mismatched at any point, stop immediately as blocker-fail and do not continue with remediation by assumption.
  • Before any kernel candidate discovery step on any distro, force a fresh package metadata refresh on the live host before evaluating available kernel builds. Use the distro's normal refresh command for the installed package manager (for example dnf makecache, yum makecache, or zypper refresh). For APT-based distros, use a hard APT refresh so stale or empty package-list files are rebuilt: rm -rf /var/lib/apt/lists/* && apt-get clean && apt-get update. If the refreshed view differs from a prior result, trust the refreshed live metadata and record that the earlier view was stale.

Red Hat Preflight (Global, Manual Tasks Only)

  • Apply this section only when the test target is an actual Red Hat subscription-managed machine and the run is manually executed.
  • Do not apply this section to CentOS, Oracle Linux, Rocky, Alma, or other RHEL-derived distributions unless the operator explicitly says the machine should be treated as Red Hat-managed for this run.
  • If the target is not actual RHEL, skip this preflight entirely and do not attempt subscription-manager.
  • Do not apply this section to ATVM automation runs that already handle subscription flow.
  • Before running test steps on Red Hat, run:
    • subscription-manager remove --all
    • subscription-manager unregister
    • subscription-manager clean
    • subscription-manager register --username "$REDHAT_SUBSCRIPTION_USER" --password "$REDHAT_SUBSCRIPTION_PASSWORD"
  • Source credentials from /home/cirrus/cds/.env.credentials.local.

SUSE Exclusion Rule (Global)

  • Do not run this test against SUSE/SLES ATVM machines.
  • SUSE ATVM machines use a local offline DVD/vault repository for packages.
  • Kernel upgrade discovery is not valid for this test unless the machine can access official SUSE repositories, which requires a SUSE subscription.
  • If the operator requests this test against any SUSE/SLES machine, stop immediately before source power-on or clone creation and report that SUSE is excluded for this test because it uses the local offline repository.

Execution Mode (Global)

  • Run this test in continuous execution mode.
  • Do not pause for additional operator prompts between steps.
  • Keep monitoring and continue automatically until the test reaches a terminal outcome (PASS or FAIL) and all required cleanup/reporting steps are completed.
  • Only stop early if a true blocker prevents safe continuation, and still complete required cleanup/reporting before returning control.
  • Time every step explicitly.
  • If any single step takes longer than 10 minutes, hard stop the test and treat it as a blocker-fail.

Naming Rule

  • Base clone VM name in vCenter: aw999-[source hostname without atvmxxx- prefix]
  • Before cloning, verify the clone VM name is not already in use.
  • If already in use, append a numeric suffix to the base name: -1, -2, ... -N until an unused name is found.
  • Use plain VM name only (no /CDSHQ-Eng/vm/ prefix) for clone destination name, and set folder separately if needed.
  • OS hostname on clone: same clone name but replace . with -

Safety Rules

  • Delete only the clone created for this test.
  • If the clone is missing or identity is uncertain, stop and do not delete any other VM.
  • If any blocker occurs after clone creation, stop the test and leave the cloned VM powered on for manual inspection.
  • Do not delete or power off the clone on blocker-fail outcomes.
  • Do not power off, delete, or otherwise tear down the clone until the final latest-kernel migration/session validation is complete and recorded. The latest-kernel reboot or reinstall is not the end of the test.

Execution Checklist

  • Treat this checklist as the run ledger for the test. Figuratively check off the items in the checklist to ensure we do and confirm each step.

  • Do not skip ahead, collapse, or reorder checklist items.

  • Do not begin teardown until every item below is checked complete.

  • If any checklist item cannot be checked, stop the test and record the blocker.

  • 0. Source /home/cirrus/cds/.env.credentials.local and verify required credential variables are present without printing secret values.

  • 1. Confirm the requested source host is not a SUSE/SLES machine.

  • 2. Remove offline hosts in skidamarink using MCP offline-host cleanup.

  • 3. Confirm source host is powered on for the inspection phase.

  • 3a. Before listing available kernel builds, inspect source repository files and hard stop if any enabled/source repo points at 192.168.3.199.

  • 4. SSH to the source host and check available kernel versions on the source before cloning.

  • 5. Build source-host kernel candidate list from all available versions after a fresh package metadata refresh. On Ubuntu, inspect the generic track first, then confirm candidate availability with alternate package listing methods if needed before deciding whether the generic track is usable.

  • 6. Apply the candidate scope rule: same major OS family only, with same minor stream preferred.

  • 7. Verify at least 2 upgrade candidates exist in the filtered candidate list.

  • 8. If fewer than 2 candidates, hard stop and end run before clone creation.

  • 9. Perform the gate check before continuing.

  • 10. Issue the source-host power-off request and wait for poweredOff.

  • 11. Confirm the source host is still poweredOff immediately before cloning.

  • 12. Determine the base clone name aw999-[source-without-atvmxxx-].

  • 13. Check whether the base clone name already exists in vCenter.

  • 14. If needed, choose the next available suffixed clone name.

  • 15. Clone the source VM on AutomatedTest-UnitTesting and default it to CDS1-ESX165 / 192.168.1.165 unless overridden.

  • 16. Pass only the clone VM name to the clone command destination.

  • 17. Detach the 2 FC PCI adapters from the cloned VM.

  • 18. Verify both FC passthrough devices are no longer present on the clone.

  • 19. Power on the clone.

  • 20. Query vCenter guest-tools for the live clone IP.

  • 21. SSH to the live clone IP using credentials from /home/cirrus/cds/.env.credentials.local.

  • 22. Change the OS hostname to the clone name with . replaced by -.

  • 23. Convert networking from static IP to DHCP.

  • 24. Remove/clean static IP configuration references.

  • 25. Reboot the clone.

  • 26. Query vCenter guest-tools again for the new live clone IP.

  • 27. SSH to the new live clone IP and verify DHCP state.

  • 28. If the clone still reports the previous static IP, fix config cleanup and repeat reboot/verify.

  • 29. Continue all remaining steps using the live DHCP IP from vCenter.

  • 30. Wipe /dev/sdb once and verify no filesystem or partition signatures remain.

  • 31. Reinstall CMC on the clone with -no-prebuilt-mtdi-nexus.

  • 32. Create the first local migration from 10 GB to 11 GB.

  • 33. If migration session creation fails, hard stop as blocker-fail.

  • 34. Wait for initial sync completion.

  • 35. Check available kernels again using full candidate listing.

  • 36. Select the first-upgrade target from the filtered candidate list.

  • 37. Verify matching dev/header packages are available for the first-upgrade target.

  • 38. Install the first-upgrade kernel and matching dev/header packages, then reboot.

  • 39. Query vCenter guest-tools again for the live clone IP after reboot.

  • 40. SSH to the rebooted clone and verify kernel plus dev/header package versions match the selected first-upgrade version.

  • 41. If versions do not match exactly, stop as blocker-fail.

  • 42. Verify the clone is online in skidamarink using cirrusdata.

  • 43. SSH to the clone and verify MTDI and Galaxy Migrate services/driver are up.

  • 44. Write sample data to the source 10 GB disk.

  • 45. Trigger sync and confirm tracking status using cirrusdata.

  • 46. Uninstall CMC.

  • 47. Run MCP host cleanup for skidamarink and remove the cloned host entry for this test clone only, regardless of online/offline status.

  • 48. Check available kernels again.

  • 49. Select the latest-upgrade target kernel from the filtered candidate list.

  • 50. Verify matching dev/header packages are available for the latest-upgrade target.

  • 51. Install the latest-upgrade kernel and matching dev/header packages, then reboot.

  • 52. Query vCenter guest-tools again for the live clone IP after reboot.

  • 53. SSH to the rebooted clone and verify kernel plus dev/header package versions match the selected latest-upgrade version.

  • 54. If versions do not match exactly, stop as blocker-fail.

  • 55. Reinstall CMC via cirrusdata with -no-prebuilt-mtdi-nexus on the latest kernel.

  • 56. Create the second local migration from 10 GB to 11 GB and wait for initial sync completion.

  • 57. If migration session creation fails, hard stop as blocker-fail.

  • 58. Confirm the machine is online in skidamarink using cirrusdata.

  • 59. SSH and verify MTDI and Galaxy Migrate services/driver are up.

  • 60. Only after steps 55-59 all pass, begin success-path cleanup.

  • 61. Power off the cloned machine.

  • 62. Delete the cloned VM and its disks from vCenter inventory.

  • 63. Run final MCP host cleanup for skidamarink and remove the cloned host entry for this test clone only.

  • 64. If a blocker-fail occurred after clone creation, leave the cloned VM powered on and present in inventory for manual inspection.

  • 65. Append the current run to the summary and results files with the required host metadata, kernel progression, execution summary, final outcome, and total test duration.

Test Procedure

The Execution Checklist above is the authoritative run ledger. Use the procedure below as the detailed action reference for each checklist item. 0. Credential gate:

  • Before any MCP, vCenter, SSH, Red Hat subscription, or CMC action, load credentials with set -a; source /home/cirrus/cds/.env.credentials.local; set +a.
  • Verify required variables are present without printing secret values: VCENTER_HOST, VCENTER_USER, VCENTER_PASSWORD, ATVM_TARGET_USER, ATVM_TARGET_PASSWORD, REDHAT_SUBSCRIPTION_USER, REDHAT_SUBSCRIPTION_PASSWORD, CMC_GCSTAGE_URL, CMC_GCSTAGE_REGISTRATION_CODE, and CIRRUS_API_TOKEN.
  • If any required variable is missing, hard stop before powering on or modifying any VM.
  • Do not parse the credential file with grep/awk as the authority; source it and inspect the environment because entries may use export KEY=....
  1. Confirm the requested source host is not a SUSE/SLES machine. If it is SUSE/SLES, hard stop immediately and do not power on, inspect, or clone the machine.
  2. Remove offline hosts in skidamarink using MCP offline-host cleanup.
  3. Confirm source host is powered on for the inspection phase. If it is powered off, power it on. 3a. Before listing available kernel builds, inspect the source host's package repository configuration files.
    • Check the distro-appropriate repo sources, such as /etc/yum.repos.d/*.repo, /etc/apt/sources.list, /etc/apt/sources.list.d/*, /etc/zypp/repos.d/*.repo, and equivalent package-manager source files that exist on the machine.
    • If any enabled/source repository contains 192.168.3.199, treat the machine as using the local offline DVD/vault repository.
    • Hard stop before kernel candidate discovery, fail the test, and do not clone the machine.
    • Power off the source VM after inspection and confirm vCenter reports poweredOff.
    • Append the FAIL result to both result files and explicitly note that the run was skipped because the source package repositories point at the local offline DVD/vault repository at 192.168.3.199.
  4. SSH to the source host and check available kernel versions on the source before cloning.
  5. Build source-host kernel candidate list from all available versions (include intermediate versions, not just the latest from check-update).
    • On package-managed distros, first force a fresh metadata refresh using the package manager's normal refresh command, then use the distro-appropriate tooling to list all available kernel candidates before selecting a target.
    • On APT-based distros, use rm -rf /var/lib/apt/lists/* && apt-get clean && apt-get update instead of a plain apt update so stale or empty package-list files are rebuilt before kernel discovery.
    • On Ubuntu, inspect the generic kernel track first after the hard APT refresh, using more than one discovery method before concluding what is available. Use apt-cache madison, apt list -a, and apt-cache policy for linux-image-generic and linux-headers-generic; if needed, repeat those checks for linux-generic and the relevant HWE meta packages.
    • If the refreshed generic-track view still returns no usable upgrade candidates, pause and ask the operator whether to continue with alternate Ubuntu kernel tracks.
    • When prompting for alternate Ubuntu tracks, display the other available kernel candidates, including linux-image-generic-hwe-24.04 / linux-headers-generic-hwe-24.04 when present, and wait for explicit operator confirmation before proceeding.
  6. Candidate scope rule:
    • Include only kernels in the same major OS family as the current machine (no major-version upgrades).
    • Prefer candidates within the same minor stream as current OS/kernel when available.
  7. Verify at least 2 upgrade candidates exist in the filtered candidate list.
  8. If fewer than 2 candidates: hard stop and end run before clone creation.
  9. Gate check:
    • If step 7 triggered a stop condition, execute no further steps.
    • If no stop condition was triggered, continue with the next step.
  10. After source-host inspection is complete, issue the power-off request and wait for vCenter to report the source host as poweredOff.
  11. Confirm the source host is still poweredOff in vCenter immediately before cloning. Do not start the clone while the source VM is transitioning or pending power-off.
  12. Determine base clone name: aw999-[source-without-atvmxxx-].
  13. Before cloning, check whether that clone name already exists in vCenter.
  14. If the name exists, choose the next available suffixed name: aw999-[source-without-atvmxxx-]-1, then -2, then -N as needed.
  15. Clone source VM using the resolved unique clone name on datastore AutomatedTest-UnitTesting only, and place the clone on CDS1-ESX165 / 192.168.1.165 by default unless the operator explicitly specifies a different ESXi host.
  16. For the clone command destination name, pass only the VM name (for example aw999-ubuntu24.04-1), not an inventory path like /CDSHQ-Eng/vm/...; set folder separately if needed.
  17. Detach the 2 FC PCI adapters from the cloned VM.
  18. Verify in vCenter that both FC passthrough devices are no longer present on the clone.
  19. Power on clone.
  20. Query vCenter guest-tools for the live clone IP.
  21. SSH to the live clone IP using credentials from /home/cirrus/cds/.env.credentials.local.
  22. Change OS hostname to clone name, replacing . with -.
  23. Convert networking from static IP to DHCP.
  24. Remove/clean static IP configuration references.
  25. Reboot clone.
  26. Query vCenter guest-tools again for the new live clone IP.
  27. SSH to the new live clone IP and verify the DHCP state.
  28. If the clone still reports the previous static IP, fix static config cleanup and repeat reboot/verify.
  29. Continue all remaining steps using the live DHCP IP from vCenter and credentials from /home/cirrus/cds/.env.credentials.local.
  30. Before the first CMC install, wipe the 10GB source disk with dd if=/dev/zero of=/dev/sdb bs=1M count=32 status=progress conv=fsync, then verify that no filesystem or partition signatures remain (wipefs -n /dev/sdb, blkid /dev/sdb, file -s /dev/sdb, lsblk -f /dev/sdb). This disk prep is one-time only and must not be repeated in later stages of the test.
  31. Using cirrusdata (gcstage, project skidamarink), reinstall CMC on clone, always adding -no-prebuilt-mtdi-nexus.
  32. Create local migration from 10GB source disk to 11GB destination disk using cirrusdata.
  33. If migration session creation fails (including API/service errors such as 5xx), hard stop as blocker-fail.
  34. Wait for initial sync completion.
  35. Check available kernels again using full candidate listing (not latest-only output). Refresh package metadata first; on APT-based distros, use the hard APT refresh command from step 5.
  36. Select first-upgrade target from filtered candidate list (same major; same minor preferred), ensuring it is not the latest candidate.
  37. Verify matching dev/header packages for the selected first-upgrade target are available.
  38. Install selected first-upgrade kernel and matching dev/header packages, then reboot.
  39. Query vCenter guest-tools again for the live clone IP after reboot.
  40. SSH to the rebooted clone via the live vCenter IP and verify running kernel and installed dev/header package versions match the selected first-upgrade version.
  41. If versions do not match exactly, stop as blocker-fail.
  42. After reboot, verify clone is online in skidamarink using cirrusdata.
  43. SSH to clone and verify MTDI, Galaxy Migrate services/driver are up.
  44. Write sample data to source 10GB disk.
  45. Trigger sync and confirm tracking status using cirrusdata.
  46. Uninstall CMC.
  47. Post-uninstall cleanup checkpoint:
  • Run MCP host cleanup for skidamarink.
  • Remove the cloned VM host entry specifically via MCP (target only this test clone host), regardless of whether CDC currently reports it as online or offline.
  1. Check available kernels. Refresh package metadata first; on APT-based distros, use the hard APT refresh command from step 5.
  2. Select latest-upgrade target kernel from the filtered candidate list (same major required; same minor preferred).
  3. Verify matching dev/header packages for the selected latest-upgrade target are available.
  4. Install selected latest-upgrade kernel and matching dev/header packages, then reboot.
  5. Query vCenter guest-tools again for the live clone IP after reboot.
  6. SSH to the rebooted clone via the live vCenter IP and verify running kernel and installed dev/header package versions match the selected latest-upgrade version.
  7. If versions do not match exactly, stop as blocker-fail.
  8. Reinstall CMC via cirrusdata (gcstage, skidamarink), always adding -no-prebuilt-mtdi-nexus.
  9. Create a local migration (10GB -> 11GB) via cirrusdata and wait for initial sync completion.
  10. If migration session creation fails (including API/service errors such as 5xx), hard stop as blocker-fail.
  11. Confirm machine is online in skidamarink using cirrusdata.
  12. SSH and verify MTDI, Galaxy Migrate services/driver are up.
  13. Only after steps 55-59 all pass, begin success-path cleanup.
  14. Success-path cleanup only: power off cloned machine.
  15. Success-path cleanup only: delete cloned VM and its disks from vCenter inventory.
  16. Success-path final cleanup checkpoint:
  • Run MCP host cleanup for skidamarink.
  • Remove the cloned VM host entry specifically via MCP (target only this test clone host), regardless of whether CDC currently reports it as online or offline.
  1. Blocker-fail path after clone creation:
  • Stop test immediately after recording failure details.
  • Leave cloned VM powered on and present in inventory for manual inspection.
  • Do not run clone power-off/delete steps in blocker-fail path.

Stop Conditions

  • Requested source host is a SUSE/SLES machine.
  • Cannot verify clone identity.
  • Cannot detach required FC PCI adapters.
  • Clone cannot be created on datastore AutomatedTest-UnitTesting.
  • FC passthrough adapters remain attached after the detach/verification step.
  • DHCP transition cannot be completed (clone remains static at <INITIAL_CLONE_HOST_OR_IP>).
  • Kernel upgrade candidate criteria not met.
  • Migration session creation failed (including API/service errors such as HTTP 5xx or equivalent backend unavailability).
  • Any critical migration/service validation failure that blocks continuation.

Per-Host Test Result Record

Use one cumulative results file and append one new section per tested host.

Host Metadata

  • Test start time (UTC):
  • Test end time (UTC):
  • Test duration:
  • Operator:
  • Source VM:
  • Cloned VM name:
  • Clone origin (vCenter path/folder/cluster):
  • Final DHCP IP of clone:

Kernel / OS Tracking

  • Start OS version:
  • Start kernel version:
  • Kernel list before first upgrade (full candidate list, filtered by scope rule):
  • Kernel selected for step-up upgrade:
  • Matching dev/header packages for step-up target (availability check):
  • Kernel after step-up reboot:
  • Installed dev/header package versions after step-up:
  • Kernel list before latest upgrade (full candidate list, filtered by scope rule):
  • Kernel selected for latest upgrade:
  • Matching dev/header packages for latest target (availability check):
  • Kernel after latest reboot:
  • Installed dev/header package versions after latest upgrade:

Execution Summary (Short Bullets)

  • Clone created / FC PCI detached: PASS|FAIL - notes
  • Hostname/IP DHCP conversion: PASS|FAIL - notes
  • CMC reinstall #1: PASS|FAIL - notes
  • 10 GB source disk prep before first CMC install: PASS|FAIL - notes
  • Local migration #1 (10GB -> 11GB) initial sync: PASS|FAIL - notes
  • Step-up kernel upgrade: PASS|FAIL - notes
  • Step-up dev/header package match check: PASS|FAIL - notes
  • Online in skidamarink after step-up: PASS|FAIL - notes
  • MTDI/Galaxy Migrate service+driver health after step-up: PASS|FAIL - notes
  • Write data + tracking status: PASS|FAIL - notes
  • CMC uninstall: PASS|FAIL - notes
  • Latest kernel upgrade: PASS|FAIL - notes
  • Latest dev/header package match check: PASS|FAIL - notes
  • CMC reinstall #2: PASS|FAIL - notes
  • Local migration #2 (10GB -> 11GB) initial sync: PASS|FAIL - notes
  • Online in skidamarink after latest upgrade: PASS|FAIL - notes
  • MTDI/Galaxy Migrate service+driver health after latest upgrade: PASS|FAIL - notes
  • Clone power off and deletion (success path only): PASS|FAIL|N/A - notes

Final Outcome

  • Overall result: PASS|FAIL|PARTIAL
  • Outcome interpretation:
    • PASS: full planned test flow completed and core validation goals passed (CMC install/uninstall/reinstall, kernel step-up/latest upgrade, and post-upgrade service/driver health checks), even if non-blocking warnings occurred.
    • FAIL: a true blocker prevented completion of required validation goals.
    • PARTIAL: use only when execution stops early by operator choice or scope is intentionally reduced, not for non-blocking warnings in a completed run.
  • Blocking issue summary:
  • Follow-up actions:

Timestamp Standard

  • All recorded test timestamps must use UTC.
  • Format: YYYY-MM-DD HH:MM UTC

Result Storage Location

Store and append all per-host results in:

  • /home/aw/code/cds/tmp/tests/cmc upgrade test/cmc-upgrade-kernel-test-results.md

Also generate a run summary file in the same directory:

  • /home/aw/code/cds/tmp/tests/cmc upgrade test/cmc-upgrade-kernel-test-summary.md

Artifact Recording Rule

  • Always append the latest run outcome to the results file and summary file at the end of each run.
  • Do this for PASS, FAIL, and PARTIAL outcomes.
  • Do not leave a completed test run only in conversation; the artifact files are the source of record.
  • Include the total test runtime in both artifact files for every run.
  • If a run is still in progress when first recorded, update the runtime once the run reaches its terminal outcome.

Summary file requirements:

  • Start the file with the test file name line: Test file: cmc-upgrade-kernel-test.md
  • Title: CMC Upgrade Kernel Test Summary
  • Include test start time, test end time, and total test duration for the run
  • Include a short workflow summary (current kernel -> install CMC -> kernel upgrade -> uninstall CMC -> kernel upgrade -> install CMC)
  • Include host tested, kernel progression (start, step-up, latest), and overall result
  • Start each run section with a ## heading that includes the OS family and the final outcome, for example: ## Amazon Linux 2023 - PASS.
  • Put the OS version and the rest of the run details under that heading so the heading stays the visible OS label above the test snippet.

Duration Rule

  • Record the UTC start time when the run begins.
  • Record the UTC end time when the run reaches a terminal outcome and cleanup/reporting is complete.
  • Compute Test duration from the recorded start/end timestamps.
  • Backfill Test duration into the summary and results artifacts for any run where both timestamps are known.