Require live vCenter IP checks during ATVM test
This commit is contained in:
@@ -67,6 +67,9 @@ Validate CMC behavior across staged kernel upgrades on a cloned VM, including re
|
||||
- After source-host kernel inspection is complete, power the source VM off and re-verify in vCenter that it is powered off before cloning.
|
||||
- Detaching the 2 FC PCI passthrough adapters from the cloned VM is mandatory before any guest boot or guest-side change.
|
||||
- Verify in vCenter that both FC passthrough devices are absent before proceeding past the clone-prep stage.
|
||||
- Always use live vCenter guest-tools data to confirm the current clone IP before any SSH or polling attempt.
|
||||
- Re-check live vCenter guest-tools IP after clone power-on, after switching networking from static to DHCP, and after any reboot before attempting SSH.
|
||||
- Do not assume the previous IP is still valid after a reboot or network change.
|
||||
- Cleanup actions that remove hosts from CMC must target only the cloned host used in the current test run.
|
||||
- Treat migration session creation failures (for either migration #1 or migration #2) as blocker-fail events.
|
||||
|
||||
@@ -93,51 +96,55 @@ Validate CMC behavior across staged kernel upgrades on a cloned VM, including re
|
||||
16. Detach the 2 FC PCI adapters from the cloned VM.
|
||||
17. Verify in vCenter that both FC passthrough devices are no longer present on the clone.
|
||||
18. Power on clone.
|
||||
19. SSH to `<INITIAL_CLONE_HOST_OR_IP>` using credentials from `/home/aw/code/cds/.env.credentials.local`.
|
||||
20. Change OS hostname to clone name, replacing `.` with `-`.
|
||||
21. Convert networking from static IP to DHCP.
|
||||
22. Remove/clean static IP configuration references.
|
||||
23. Reboot clone.
|
||||
24. Find DHCP address and verify it is not `<INITIAL_CLONE_HOST_OR_IP>`.
|
||||
25. If still `<INITIAL_CLONE_HOST_OR_IP>`, fix static config cleanup and repeat reboot/verify.
|
||||
26. Continue all remaining steps using DHCP IP and credentials from `/home/aw/code/cds/.env.credentials.local`.
|
||||
27. Using `cirrusdata` (`gcstage`, project `skidamarink`), reinstall CMC on clone, always adding `-no-prebuilt-mtdi-nexus`.
|
||||
28. Create local migration from 10GB source disk to 11GB destination disk using `cirrusdata`.
|
||||
29. If migration session creation fails (including API/service errors such as 5xx), hard stop as blocker-fail.
|
||||
30. Wait for initial sync completion.
|
||||
31. Check available kernels again using full candidate listing (not latest-only output).
|
||||
32. Select first-upgrade target from filtered candidate list (same major; same minor preferred), ensuring it is not the latest candidate.
|
||||
33. Verify matching dev/header packages for the selected first-upgrade target are available.
|
||||
34. Install selected first-upgrade kernel and matching dev/header packages, then reboot.
|
||||
35. Verify running kernel and installed dev/header packages match the selected first-upgrade version.
|
||||
36. If versions do not match exactly, stop as blocker-fail.
|
||||
37. After reboot, verify clone is online in `skidamarink` using `cirrusdata`.
|
||||
38. SSH to clone and verify MTDI, Galaxy Migrate services/driver are up.
|
||||
39. Write sample data to source 10GB disk.
|
||||
40. Trigger sync and confirm tracking status using `cirrusdata`.
|
||||
41. Uninstall CMC.
|
||||
42. Post-uninstall cleanup checkpoint:
|
||||
19. Query vCenter guest-tools for the live clone IP.
|
||||
20. SSH to the live clone IP using credentials from `/home/aw/code/cds/.env.credentials.local`.
|
||||
21. Change OS hostname to clone name, replacing `.` with `-`.
|
||||
22. Convert networking from static IP to DHCP.
|
||||
23. Remove/clean static IP configuration references.
|
||||
24. Reboot clone.
|
||||
25. Query vCenter guest-tools again for the new live clone IP.
|
||||
26. SSH to the new live clone IP and verify the DHCP state.
|
||||
27. If the clone still reports the previous static IP, fix static config cleanup and repeat reboot/verify.
|
||||
28. Continue all remaining steps using the live DHCP IP from vCenter and credentials from `/home/aw/code/cds/.env.credentials.local`.
|
||||
29. Using `cirrusdata` (`gcstage`, project `skidamarink`), reinstall CMC on clone, always adding `-no-prebuilt-mtdi-nexus`.
|
||||
30. Create local migration from 10GB source disk to 11GB destination disk using `cirrusdata`.
|
||||
31. If migration session creation fails (including API/service errors such as 5xx), hard stop as blocker-fail.
|
||||
32. Wait for initial sync completion.
|
||||
33. Check available kernels again using full candidate listing (not latest-only output).
|
||||
34. Select first-upgrade target from filtered candidate list (same major; same minor preferred), ensuring it is not the latest candidate.
|
||||
35. Verify matching dev/header packages for the selected first-upgrade target are available.
|
||||
36. Install selected first-upgrade kernel and matching dev/header packages, then reboot.
|
||||
37. Query vCenter guest-tools again for the live clone IP after reboot.
|
||||
38. SSH to the rebooted clone via the live vCenter IP and verify running kernel and installed dev/header package versions match the selected first-upgrade version.
|
||||
39. If versions do not match exactly, stop as blocker-fail.
|
||||
40. After reboot, verify clone is online in `skidamarink` using `cirrusdata`.
|
||||
41. SSH to clone and verify MTDI, Galaxy Migrate services/driver are up.
|
||||
42. Write sample data to source 10GB disk.
|
||||
43. Trigger sync and confirm tracking status using `cirrusdata`.
|
||||
44. Uninstall CMC.
|
||||
45. Post-uninstall cleanup checkpoint:
|
||||
- Run MCP offline-host cleanup for `skidamarink`.
|
||||
- If the cloned VM is still marked online after uninstall, remove that cloned VM host entry specifically via MCP (target only this test clone host).
|
||||
- Because CMC status can lag behind VM state, poll briefly for status transition; if still online, perform targeted MCP host removal for the tested clone.
|
||||
43. Check available kernels.
|
||||
44. Select latest-upgrade target kernel from the filtered candidate list (same major required; same minor preferred).
|
||||
45. Verify matching dev/header packages for the selected latest-upgrade target are available.
|
||||
46. Install selected latest-upgrade kernel and matching dev/header packages, then reboot.
|
||||
47. Verify running kernel and installed dev/header packages match the selected latest-upgrade version.
|
||||
48. If versions do not match exactly, stop as blocker-fail.
|
||||
49. Reinstall CMC via `cirrusdata` (`gcstage`, `skidamarink`), always adding `-no-prebuilt-mtdi-nexus`.
|
||||
50. Create a local migration (10GB -> 11GB) via `cirrusdata` and wait for initial sync completion.
|
||||
51. If migration session creation fails (including API/service errors such as 5xx), hard stop as blocker-fail.
|
||||
52. Confirm machine is online in `skidamarink` using `cirrusdata`.
|
||||
53. SSH and verify MTDI, Galaxy Migrate services/driver are up.
|
||||
54. Success-path cleanup only: power off cloned machine.
|
||||
55. Success-path cleanup only: delete cloned VM and its disks from vCenter inventory.
|
||||
56. Success-path final cleanup checkpoint:
|
||||
46. Check available kernels.
|
||||
47. Select latest-upgrade target kernel from the filtered candidate list (same major required; same minor preferred).
|
||||
48. Verify matching dev/header packages for the selected latest-upgrade target are available.
|
||||
49. Install selected latest-upgrade kernel and matching dev/header packages, then reboot.
|
||||
50. Query vCenter guest-tools again for the live clone IP after reboot.
|
||||
51. SSH to the rebooted clone via the live vCenter IP and verify running kernel and installed dev/header package versions match the selected latest-upgrade version.
|
||||
52. If versions do not match exactly, stop as blocker-fail.
|
||||
53. Reinstall CMC via `cirrusdata` (`gcstage`, `skidamarink`), always adding `-no-prebuilt-mtdi-nexus`.
|
||||
54. Create a local migration (10GB -> 11GB) via `cirrusdata` and wait for initial sync completion.
|
||||
55. If migration session creation fails (including API/service errors such as 5xx), hard stop as blocker-fail.
|
||||
56. Confirm machine is online in `skidamarink` using `cirrusdata`.
|
||||
57. SSH and verify MTDI, Galaxy Migrate services/driver are up.
|
||||
58. Success-path cleanup only: power off cloned machine.
|
||||
59. Success-path cleanup only: delete cloned VM and its disks from vCenter inventory.
|
||||
60. Success-path final cleanup checkpoint:
|
||||
- Run MCP offline-host cleanup for `skidamarink`.
|
||||
- If the cloned VM is still marked online at the end of the test, remove that cloned VM host entry specifically via MCP (target only this test clone host).
|
||||
- Because CMC status can lag behind VM deletion/power-off, wait/poll briefly first; if still online, perform targeted MCP host removal for the tested clone.
|
||||
57. Blocker-fail path after clone creation:
|
||||
61. Blocker-fail path after clone creation:
|
||||
- Stop test immediately after recording failure details.
|
||||
- Leave cloned VM powered on and present in inventory for manual inspection.
|
||||
- Do not run clone power-off/delete steps in blocker-fail path.
|
||||
|
||||
Reference in New Issue